TM 1-1270-476-30
4-163
4-9. BRANCHED WIRING HARNESS ASSEMBLY (W10) REPAIR (cont)
6. CONNECTOR J1, P3, OR P14
REPLACEMENT
REMOVAL
a. Loosen two screwlocks (1) and disconnect
faulty connector as follows:
J1 (2) from focus adjust CCA connector
A37P1
P3 (3) from scanner optics assembly
connector A32J1
P14 (4) from relay bracket assembly
connector A39J1
b. Remove applicable connector J1 (2). P3
(3), or P14 (4) from wires (para 2-5).
INSTALLATION
c. Install applicable replacement connector J1
(2), P3 (3), or P14 (4) on wires (para 2-5).
d. Connect connector as follows and tighten
two screwlocks (1).
J1 (2) to focus adjust CCA connector A37P1
P3 (3) to scanner optics assembly
connector A32J1
P14 (4) to relay bracket assembly connector
A39J1
END OF TASK