TM 1-1270-476-30
4-167
4-10. BRANCHED WIRING HARNESS ASSEMBLY (W10) OIP REPAIR (cont)
1. CONNECTOR P11 REPLACEMENT
INSTALLATION
REMOVAL
a. Loosen two screwlocks (1) and disconnect
faulty connector P11 (2) from connector
B1J1 (3).
b. Remove connector P11 (2) from wires (para
2-5).
INSTALLATION
c. Install replacement connector P11 (2) on
wires (para 2-5).
d. Connect connector P11 (2) to CCA
connector B1J1 (3) and tighten two
screwlocks (1).
END OF TASK