TM 1-1270-476-30
4-247
4-29. CONTROL PANEL ASSEMBLY 2A1 REPAIR (cont)
q. Disconnect ohm meter leads from
connector J3 (1).
END OF TASK
13. RESISTOR R6 ADJUSTMENT
a. Connect ohm meter leads between
contacts 2 and 53 of connector J3 (1).
b. Move R6 thumbwheel (2) until
approximately 570 to 630 ohms is read.
NOTE
It may be necessary to loosen setscrews (3)
and reposition thumbwheel (2) to obtain
reading.
c. Repeat steps c through p (12 above).
d. Disconnect ohm meter leads from
connector J3 (1).
END OF TASK