TM 1-1270-476-30
4-358
4-42. TADS POWER SUPPLY ASSEMBLY REPAIR (cont)
c. Clean surfaces of TADS power supply
assembly (5) where contact strip(s) (1 and
2) are to be mounted with a cloth and
trichloroethane.
d. Peel backing off new contact strip(s) (1 and
2) and install on TADS power supply
assembly (3).
e. Apply light pressure to contact strip(s) (1
and 2) to ensure contact is made between
TADS power supply assembly (3) and
adhesive on contact strip(s) (1 and 2).
f. Have installation inspected.
g. Install access cover (1 above).
END OF TASK