TM 1-1270-476-30
4-357
4-42. TADS POWER SUPPLY ASSEMBLY REPAIR (cont)
6. CONTACT STRIP REPLACEMENT
NOTE
This procedure is for replacing the short or
long contact strips.
REMOVAL
a. Remove access cover (1 above).
b. Remove damaged contact strip(s) (1 and 2)
from TADS power supply assembly (3) by
pulling off with pliers.
INSTALLATION
WARNING
TRICHLOROETHANE
Flammable, toxic, irritating. Can cause
breathing problems, eye damage.
At 325°F, gives off phosgene gas, which can
cause death or serious injury.
Dont: Use near flames or sparks, let it get
on skin, or breathe vapors.
Do: Use in well-ventilated area, close
containers when not using. Wear acid-type
safety goggles, rubber gloves, and rubber
apron.
If it contacts skin or eyes, wash affected
areas with running water. Get medical help
at once.
If you experience any breathing problems,
get to fresh air at once.