TM 1-1270-476-304-3534-42. TADS POWER SUPPLY ASSEMBLY REPAIR (cont)g. Apply corrosion inhibitive sealing and coating compound to mounting hardware (para 2-6). Use class 1A application.CAUTIONUse care when sliding chassis on power components assembly to keep from damaging equipment.h. Put chassis (6) on power components assembly (11) leaving enough room to connect P1 (9).i. Connect connector P1 (9) to connector J1 (10). Tighten two screwlocks (7). Position plastic shield (8) over connector P1 (9).j. Slide chassis (6) completely over power components assembly (11).k. Install screws (3), (2), and (1), lockwashers(4), and washers (5).l. Torque screws (3), (2), and (1), to 6 in-lb.m. Install CCA A1, A3, and A5 and remove tags (1 above).END OF TASK