TM 1-1270-476-30
4-353
4-42. TADS POWER SUPPLY ASSEMBLY REPAIR (cont)
g. Apply corrosion inhibitive sealing and
coating compound to mounting hardware
(para 2-6). Use class 1A application.
CAUTION
Use care when sliding chassis on power
components assembly to keep from damaging
equipment.
h. Put chassis (6) on power components
assembly (11) leaving enough room to
connect P1 (9).
i. Connect connector P1 (9) to connector J1
(10). Tighten two screwlocks (7). Position
plastic shield (8) over connector P1 (9).
j. Slide chassis (6) completely over power
components assembly (11).
k. Install screws (3), (2), and (1), lockwashers
(4), and washers (5).
l. Torque screws (3), (2), and (1), to 6 in-lb.
m. Install CCA A1, A3, and A5 and remove
tags (1 above).
END OF TASK