TM 1-1270-476-30
4-362
4-42. TADS POWER SUPPLY ASSEMBLY REPAIR (cont)
9. CONNECTOR J1 OR J2 CONTACT
REPLACEMENT
REMOVAL
NOTE
Remove and replace lacing and tying tape as
required.
a. Remove access cover (1 above).
b. Remove safety wire (1).
c. Remove nut (2) from connector to be
repaired, J1 (3) or J2 (4), and pull
connector out of mounting hole for access.
d. Remove faulty contact(s) from connector
(para 2-5).
INSTALLATION
e. Install replacement contact(s) (para 2-5).
f. Install connector J1 or J2 in chassis and
secure with nut (2). Torque to 110 in-lb.
g. Install safety wire (1).
h. Have installation inspected.
i. Install access cover (1 above).
END OF TASK