TM 1-1270-476-30
4-173
4-12. DAY SENSOR SUBASSEMBLY REPAIR (cont)
3. CAPACITOR ASSEMBLY A19
REPLACEMENT
WARNING
Before performing maintenance/repair,
discharge all high-voltage capacitors (para
2-4).
REMOVAL
a. Cut lacing and tying tape (1) securing
connectors A19J1 (2) and A19J2 (3).
b. Disconnect connectors A19J1 (2) and
A19J2 (3).
Mating
Connector
Connector
A19J1
A19P1
A19J2
1A5W1P14
c. Cut lacing and tying tape securing capacitor
assembly A19 (4) wires to wire harness
1A5W1 (5).
d. Remove capacitor assembly A19 (4) by
removing two screws (6) and washers (7).
INSTALLATION
e. Remove old corrosion inhibitive sealing and
coating compound from mounting hardware
(para 2-6).
f. Apply corrosion inhibitive sealing and
coating compound to mounting hardware
(para 2-6). Use class 1A application.
g. Install capacitor assembly A19 (4) using
two screws (6) and washers (7).
h. Install lacing and tying tape to secure
capacitor assembly wires to wire harness
1A5W1 (5).