TM 1-1270-476-30
4-47
4-3. TADS TURRET ASSEMBLY REPAIR (cont)
5. DAY OR NIGHT SENSOR SHROUD
ELECTRONIC SHIELDING GASKET
REPLACEMENT
NOTE
This procedure is for replacing day sensor
electronic shielding gasket (1). This procedure
can also be used to replace night sensor
electronic shielding gasket (2).
REMOVAL
a. Remove day sensor electronic shielding
gasket (1) from shroud support assembly
(3).
INSTALLATION
b. Remove old conducting silicone adhesive
from shroud support assembly (para 2-6).
c. Apply conducting silicone adhesive to
shroud support assembly sealing groove
(para 2-6).
d. Position new gasket in sealing groove.
Maintain bond line thickness between outer
surface of gasket and shroud support as
shown on the illustration.
END OF TASK
BOND LINE THICKNESS
0.045 TO 0.055 INCH
210-260A
3
1
2