TM 1-1270-476-30
4-51
4-3. TADS TURRET ASSEMBLY REPAIR (cont)
n. Let adding sealing compound cure for 16
hours minimum at 67 to 87°F.
o. Remove teflon tape (11) mold from inter M2
(5).
p. Apply corrosion inhibitive sealing and
coating compound to two screws (7) (para
2-6). Use class 1A application.
q. Install replacement time totalizing meter M2
(5) on mounting plate (6) with two screws
(7), washers (8), and lockwashers (9).
r. Apply corrosion inhibitive sealing and
coating compound to two screws (2) (para
2-6). Use class 1A application.
s. Install meter assembly (1) with two screws
(2), washers (3), and spacers (4).
END OF TASK