POWER DISTRIBUTION BLOCK (FUSE/RELAY HOLDER)
STARTER INTERLOCK RELAY (CRSI)

Maintenance and Parts Manual For MT3 Standard Aircraft Towing System \(SATS\)
Page Navigation
  431    432    433    434    435  436  437    438    439    440    441  
img
.
0122
TM 1-1740-221-13&P&P
POWER DISTRIBUTION BLOCK (FUSE/RELAY HOLDER) - (CONTINUED)
Figure 2. Power Distribution Block (Dash)
END OF TASK
REMOVAL
PARK RELAY (SHIFTER) (CRS)
NOTE
Identiication of all relays is accomplished by removing cover (Figure 1, Item 1), see decal
inside cover.
Always replace fuses with same amperage rating fuses.
Distribution Block relays are all exactly alike (interchangeable) which could help when
troubleshooting circuit malfunctions.
Components in the distribution block are grouped together to ease with maintenance.
1.
Disconnect battery negative cables (WP 0111).
2.
Remove distribution box cover (Figure 2, Item 1).
3.
Locate Park Relay (CRS) (Figure 2, Item 2, Relay A) or reference the decal inside distribution box cover.
4.
Carefully pull relay from socket.
01222