0102
TM 1-1740-221-13&P&P
Washer Fluid Reservoir - (CONTINUED)
INSTALLATION
NOTE
If overhang of shifter plate (Figure 1, Item 1) exists, go to Step 1. If not, proceed to Step 2.
1.
If needed, align shim (Figure 1, Item 3) with mount holes (Figure 1, Item 10) on shifter plate (Figure 1, Item
2).
2.
Align reservoir (Figure 1, Item 4) with mount holes on shifter plate (Figure 1, Item 2) and install two mount
screws (Figure 1, Item 5).
3.
Connect washer luid reservoir power supply plug (Figure 1, Item 9) to receptacle (Figure 1, Item 6) on
reservoir (Figure 1, Item 4).
4.
Connect washer supply tubing (Figure 1, Item 8) to hose barb (Figure 1, Item 7) on reservoir (Figure 1, Item
4).
5.
Fill reservoir (Figure 1, Item 4).
6.
Perform Maintenance Operation Check.
END OF TASK
END OF WORK PACKAGE
01022