TM 1-1270-476-30
4-180
4-12. DAY SENSOR SUBASSEMBLY REPAIR (cont)
h. Connect connector 1A5A13J1 (4) to
connector 1A5W1P3. Secure connectors
using lacing and tying tape (2).
i. Connect applicable connector(s) and
secure using lacing and tying tape (2).
Mating
Connector
Connector
1A5P6
1A5A15J1
1A5P9
1A5A14J1
1A5J1
1A5A12P1
1A5J2
1A5A12P2
j. Install 21 Hz filter assembly (1) (step 8
above).
k. Have installation inspected.
END OF TASK