TM 1-1270-476-30
4-179
4-12. DAY SENSOR SUBASSEMBLY REPAIR (cont)
9. MOTOR AND GEAR ASSEMBLY A13
REPLACEMENT
REMOVAL
a. If installed, remove 21 Hz filter assembly
(1) (step 8 above).
b. Remove lacing and tying tape (2) from
connectors as necessary to access motor
and gear assembly A13 (3) and connector
1A5A13J1 (4).
Mating
Connector
Connector
1A5P6
1A5A15J1
1A5P9
1A5A14J1
1A5J1
1A5A12P1
1A5J2
1A5A12P2
c. Cut lacing and tying tape (2) and
disconnect connector 1A5A13J1 (4) from
connector 1A5W1P3.
d. Remove motor and gear assembly A13 (3)
by removing two screws (5).
INSTALLATION
e. Remove old corrosion inhibitive sealing and
coating compound from screws (5) (para
2-6).
f. Apply corrosion inhibitive sealing and
coating compound to two screws (5) (para
2-6). Use class 1A application.
g. Install motor and gear assembly A13 (3)
using two screws (5).