TM 55-1680-320-23&P
2-64 Change 8
2-22.A.
CABLE CUTTER ASSEMBLY - REPAIR (cont)
2-22.A.
NOTE
After activation, the cable cutter assembly
must be repaired (rebuilt) prior to installing
the new cable cutter assembly.
NOTE
The cartridge has a combined shelf life
and installed life of not more than six years
from date of manufacture. The maximum
installed life is three years. Cartridge
replacement is mandatory when the maxi-
mum combined shelf and installed life of
six years or max. installed life has expired.
Discarded cartridge is to be disposed of
IAW DOD and army regulations governing
the disposal of munitions. Perform step A
for cartridge replacement only. Due to ex-
piration of cartridge service life.
1. Disassembly.
a. Cut lockwire and remove cartridge (2) from
Cable Cutter Assembly (1). Discard cartridge
(2).
GO TO NEXT PAGE