0066
TM 1-1740-221-13&P&P
FUEL SOLENOID (START/SHUTDOWN) - (CONTINUED)
Figure 1. Shut-Off Solenoid (Removal and Installation)
END OF TASK
REMOVAL
WARNING
The use of Personal Protective Equipment (PPE) is required when using or handling hazardous
materials associated with operating and maintaining equipment (jet fuel, hydraulic luid, brake
luid, ethylene glycol, cleaning solvents, compressed air, and engine/axle oil). Failure to use
PPE when handling these materials could result in injury or death.
1.
2.
3.
Disconnect electrical connector (Figure 1, Item 1) from fuel solenoid (Figure 1, Item 2).
4.
Remove two bolts (Figure 1, Item 3).
5.
Pull straight up and remove fuel solenoid (Figure 1, Item 2).
END OF TASK
00662