0023 00
TM 1-1730-201-13&P
CLEANING
WARNING
CLEANING SOLVENT MIL-PRF-680
Is combustible and toxic to eyes, skin, and respiratory tract. Wear protective gloves and
goggles/face shield. Avoid repeated or prolonged contact. Use only in well ventilated areas
(or use approved respirator as determined by local safety/industrial hygiene personnel). Keep
away from open ames or other sources of ignition.
Wash all parts in Cleaning Compound, Solvent.
TEST AND INSPECTION
1.
Inspect the plate, tube, and sleeve for cracks or breaks. Weld a broken plate. Inspect the lever and links for
breaks or cracks. Weld a broken lever or link. Grease bolts and shaft of base assembly with Grease, Plug
Valve.
2.
Replace any defective parts.
INSTALLATION
1.
Position the lever (Figure 1, Item 1) and two links (Figure 1, Item 2) on the sleeve (Figure 1, Item 8) and
secure with the two bolts (Figure 1, Item 3 and 10).
2.
Install the sleeve (Figure 1, Item 8), spring (Figure 1, Item 6) and retaining ring (Figure 1, Item 7) on the base
assembly (Figure 1, Item 9).
3.
Position the jack on the base assembly and secure with two bolts and nuts.
4.
Install the other jack in the same manner.
LUBRICATION
Lubricate every 60 days with Grease, Plug Valve.
END OF WORK PACKAGE
0023 00-2