TM 1-1270-476-30
4-6
4-2. TADS TURRET ASSEMBLY REPLACEMENT (cont)
i. Disconnect the following connectors:
P871 (8) from W1J1 (9)
P870 (10) from W1J2 (11)
P869 (12) from W3J3 (13)
P868 (14) from W3J4 (15)
j. Remove ORT cable cover
(TM 1-1270-476-20).
CAUTION
Optics are exposed during this task. When
optics are exposed for more than 5 minutes
they must be protected from contamination.
Careless handling of equipment could result in
contaminated or damaged optics.
NOTE
The AND does not have to be removed if
there is a cable guide attached to the AND
and the cables on both sides of the ORT are
retained by the cable guide.
The AND does not have to be removed if
there is no cable guide, but the cables on
both sides of the ORT are free of the
instrument panel.
The AND must be removed if the cables on
either side of the ORT are retained or
wedged by the instrument panel.
Go to step k below if AND does not have to
be removed from ORT.
k. Remove AND assembly
(TM 1-1270-476-20).
NOTE
To gain access to left side swivel-foot screw,
the left instrument panel flood light lens and
lamp must be removed.
l. Remove left instrument panel flood light
lens and lamp (TM 1-1520-238-23).