TM 1-1270-476-30
4-380
4-45. LASER ELECTRONICS UNIT (LEU) HARNESS ASSEMBLY W1 REPAIR (cont)
i. Lightly tug on wire to check that wire
contact holds.
j. Place wire in bundle. Secure harness
assembly using spot ties and clamps. Slide
sleeving (1) over filter (2).
k. Perform electrical tests.
(1) With multimeter set on lowest
resistance scale, make a point-to-point
continuity measurement of each wire
per the applicable wire running list.
Verify meter indicates less than 1 ohm
for each wire.
(2) With multimeter set on highest
resistance scale, test each conductor to
all other conductors, conductor shields
and connector shells. Verify resistance
is 100 megohms or more.
l. Have installation inspected.
m. Install LEU harness assembly W1 (1
above).
END Of TASK