0034
TM 1-1740-221-13&P&P
STARTER - (CONTINUED)
INSTALLATION
WARNING
Remove all jewelry such as rings, ID tags, watches, and bracelets. If jewelry or tools contact a
battery positive terminal, a direct short will result in instant heating or electric shock, damage to
equipment, and injury to personnel.
NOTE
Refer to torque charts (WP 0142) for mount bolt and nut torques.
1.
Position starter assembly (Figure 1, Item 10).
2.
Install starter mount nut (Figure 1, Item 8).
3.
Install starter mount bolt (Figure 1, Item 9).
4.
Install wire into starter solenoid (Figure 1, Item 7).
5.
Install 3 wires; #1 solid red (Figure 1, Item 5), #1 red & white striped (Figure 1, Item 4) and positive battery
cable (Figure 1, Item 3).
6.
Secure wires to starter solenoid terminal (Figure 1, Item 6) with washer (Figure 1, Item 2) and nut
(Figure 1, Item 1). Torque nut to 90 inch pounds.
7.
8.
Perform Maintenance Operation Check.
9.
END OF TASK
END OF WORK PACKAGE