0008 00
TM 1-1730-213-13&P
JACK WILL NOT RAISE CAPACITY LOAD
SYMPTOM
Jack will not raise capacity load
MALFUNCTION
Pump assembly defective
CORRECTIVE ACTION
MALFUNCTION
Ram defective
CORRECTIVE ACTION
JACK WILL NOT RISE TO CAPACITY HEIGHT
SYMPTOM
Jack will not rise to capacity height
MALFUNCTION
Fluid level low.
CORRECTIVE ACTION
MALFUNCTION
Closed air vent assembly
CORRECTIVE ACTION
MALFUNCTION
Sticking intake valve in pump assembly
CORRECTIVE ACTION
Pump rapidly to dislodge. Report to ASB maintenance if malfunction persists.
RAM RISES AND FALLS DURING EACH STROKE
SYMPTOM
Ram rises and falls during each stroke
MALFUNCTION
Release valve open slightly
CORRECTIVE ACTION
MALFUNCTION
Pump assembly defective
CORRECTIVE ACTION
0008 00-2