TM 1-1500-204-23-11
(c) Wet the blind bolt with MIL-PRF-81733
(e) Inspect the fastener for acceptable
sealant. The sealant should be spread
installation per the requirements of table
around the nut of the fastener.
7-2 and 7-3. Use the break-off gauge
(d) Install the wet blind bolt using pneu-
matic or hand tools listed in tables
3-4 through 3-6 for the corresponding
fastener. Hold installation tooling per-
pendicular to the repair surface while
installing the fastener.
Blind Fastener Inspection Requirements (VISU--LOK)
VISU-LOK & VISU-LOK II
GAGE NEEDED
VISU-LOK
VISU-LOK II
BREAK-OFF
DIAMETER
MONOGRAM
STANDARD
PART NUMBER
PART NUMBER
LIMITS
GAUGE
GAUGE
-5
4F5
MGF-5
+.020/-.068
-6
PLT110
PLT5110
4F6
MGF-6
+.015/-.073
-8
PLT150
PLT5150
4F8
MGF-8
+.010/-.088
-10
PLT170
PLT5170
4F10
MGF-10
+.010/-.083
-12
4F12
MGF-12
+.010/-.093
-5
+.082/-.006
MGFA-5
A4F5LS
-6
+.072/-.016
MGFA-6
A4F6LS
-8
PLT120
PLT5120
+.072/-.026
MGFA-8
A4F8LS
-10
+.072/-.031
MGFA-10
A4F10LS
-12
+.072/-.031
MGFA-12
A4F12LS
-5
3P5
+.088/+.000
MGP-5
-6
PLT130
PLT5130
3P6
+.098/+.010
MGP-6
-8
3P6
+.098/+.010
MGP-8
-5
MGP-5
+.088/+.000
3P5
-6
PLT210
PLT5210
MGP-6
+.098/+.010
3P6
-8
PLT250
PLT5250
MGP-8
+.135/+.047
3P8
-10
PLT270
PLT5270
MGP-10
+.146/+.043
3P10
-12
MGP-12
+.152/+.049
-5
A3P5
MGP-5
+.088/+.000
-6
A3P6
MGPA-6
+.103/+.015
-8
PLT220
PLT5220
A3P8
MGPA-8
+.130/+.032
-10
A3P10
MGPA-10
+.130/+.027
-12
A3P12
MGPA-12
+.130/+.027
-5
3P5
MGP-5
+.088/+.000
-6
PLT230
PLT5230
3PA6
MGPA-6
+.103/+.015
-8
3P8
MGP-8
+.135/+.047