TM 1-1270-476-30
4-281
4-34. LEFT AND RIGHT HANDGRIP (LHG, RHG) ASSEMBLIES 2A4 AND 2A5 REPAIR (cont)
INSTALLATION
CAUTION
Components inside the RHG contain
electrostatic discharge sensitive (ESDS)
devices. Refer to paragraph 2-8 for handling
requirements before starting this task to
prevent damage.
e. Remove old grey RTV from mounting hole
(para 2-6).
f. Solder wires (7) to switch and remove tags.
g. Have solder joints inspected.
h. Apply grey RTV around inside surface of
mounting hole (para 2-6).
i.
Position switch with keyway alined in
mounting hole as indicated below and
press in firmly.
j.
Tape switch in place. Leave taped until grey
RTV is cured (para 2-6), then remove tape.
k. Install knob (5) and tighten setscrew (6).
END OF TASK
Handgrip
Switch
Keyway
Points To
LHG
S5 (1)
DVO
S6 (2)
ST
RHG
S3 (3)
BLK
S6 (4)
LT