0016 00
TM 1-1730-202-13&P
CLEANING
WARNING
DEGREASING SOLVENT, MIL-PRF-680
Degreasing solvent, MIL-PRF-680, is combustible and toxic to eyes, skin and respiratory tract.
Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use
only in well ventilated areas (or use approved respirator as determined by local safety/industrial
hygiene personnel). Keep away from open ames or other sources of ignition.
Clean all parts in Cleaning Solvent and dry thoroughly.
REPAIR OR REPLACEMENT
Remove nicks and burrs from threads and straighten distorted parts. Replace any part damaged beyond repair.
ASSEMBLY
1.
Install two new rivets (Figure 1, Item 6) if removed during disassembly. Install the wingnut (Figure 1, Item 4)
on the clamp eyebolt (Figure 1, Item 5).
2.
Install the clamp cam handle (Figure 1, Item 9), two washers (Figure 1, Item 2 and 3) and the cam stud (Figure
1, Item 1) on tie front half clamp (Figure 1, Item 8).
TEST AND INSPECTION
Inspect all parts for cracks, breaks, distortion and damaged threads.
INSTALLATION
END OF WORK PACKAGE
0016 00-2