TM 1-1270-476-30
4-275
4-32. SPECIAL PURPOSE CABLE ASSEMBLY 2W5 REPLACEMENT (cont)
e. Remove connector 2W5P2 ground wire
from panel (7) by removing screw (8).
Reinstall screw (8).
f. Unscrew and disconnect connector 2W5P2
(9) from IVD electronics assembly (10).
g. Remove two screws (11) from mounting
bracket assembly (12) and slide mounting
bracket assembly (12) down to clear
connector 2W5P1 (3). Pull cable 2W5 (5)
through mounting bracket assembly (12).
h. Remove lacing and tying tape (13) as
required.
i. Remove cable 2W5 (5).