TM 1-1270-476-30
4-207
4-19. SOLID STATE CAMERA COVER ASSEMBLY A4 REPAIR (cont)
d. Apply RTV silicone sealing compound
evenly to retaining pad as required to
maintain bondline thickness of 0.010 to
0.030 inches (para 2-6).
e. Install retaining pad (1) on camera cover (2)
allowing even clearance around RF filter
mounting screw (3) and filter terminal A1-3.
f. Ensure that retaining pad edge is located
approximately 0.30 inches from end of
camera cover.
g. Remove trapped air using roller of
squeegee while maintaining bondline
thickness.
END OF TASK
4. MOUNTING PLATE REPLACEMENT
REMOVAL
a. Remove mounting plate (1) by carefully
scraping and peeling.
b. Remove adhesive residue from camera
cover (2) where mounting plate was
removed.
INSTALLATION
c. Clean and prepare camera cover surface
where mounting plate is to be bonded (para
2-6).
d. Apply epoxy adhesive evenly to mounting
plate as required to maintain bondline
thickness of 0.005 to 0.020 inches (para
2-6).
e. Install mounting plate (1) within 0.12 inches
of camera cover edge and approximately
0.25 inches from camera cover (2) end.
f. Remove trapped air while maintaining
bondline thickness by applying even
pressure to mounting plate.
END OF TASK
1
2
232-056A
1
2
232-057