0008
TM 1-1740-221-13&P&P
ENGINE TROUBLESHOOTING - (CONTINUED)
MALFUNCTION - BRANCH 3.
MALFUNCTION - Flywheel gear teeth are not broken.
ACTION
END OF TEST
TROUBLESHOOTING PROCEDURE
ENGINE STARTER FAILS TO DISENGAGE
BRANCH 1.
1.
Disconnect batteries and ohms test engine ignition switch SW1 (WP 0120) for continuity (FO-1, Line 9).
CONDITION/INDICATION
DECISION
YES Proceed to Step 2.
BRANCH 2.
2.
Ohms check starter (WP 0123) contacts (FO-1, line 2) for shorted condition.
CONDITION/INDICATION
Contacts shorted?.
DECISION
NO Proceed to Step 3.
MALFUNCTION - BRANCH 3.
MALFUNCTION - Ohms starter relay contact are not in shorted.
ACTION
END OF TEST
TROUBLESHOOTING PROCEDURE
ENGINE RPM WILL NOT RETURN TO IDLE POSITION
00088