INSPECTION OF INSTALLED ITEMS
TEST AFTER OVERHAUL

ENGINE AND TRANSMISSION OILS, FUELS AND ADDITIVES FOR ARMY AIRCRAFT
Page Navigation
  33    34    35    36    37  38  39    40    41    42    43  
img
. .
TM 1-1730-213-13&P
0016 00
OPERATOR MAINTENANCE
JACK, HYDRAULIC, TRIPOD, 12TON FIXED-HEIGHT
PART NO. 1214-151 NSN 1730-00-554-5436 NSN 1730-00-554-5436
PREPARATION FOR USE AFTER ASSEMBLY
INITIAL SETUP:
Materials/Parts
Hydraulic Fluid (WP 0025 00, Item 3)
1.
Fill the reservoir with 1.7 gallons of Hydraulic Fluid, speciication MIL-H-5606 or equivalent.
NOTE
For temperatures below -28.9C (29F) use 3 parts of Hydraulic Fluid to 1 parts of naphtha,
speciication TT-N95.
2.
Check tightness of bolts.
3.
Check operation of retractable casters.
Figure 1.
Jack Assembly.
4.
Operate jack several times to bleed out trapped air. If air is still present, pump jack to full extension, remove
plunger, open the valve (Figure 1, Item 11). Lower jack as rapidly as possible without overlowing the pump.
With luid level at the top of the reservoir, replace the plunger.
END OF WORK PACKAGE
0016 00-1/2 blank