TM 55-1680-320-23 & P
2-67. ELECTRICAL CABLES AND CONNECTORS - REPLACE (cent)
2-67
i.
j.
Remove clamp (20) from connector (21) by
removing screws (22).
Using a suitable pin removal tool, remove pins
from connector (21).
k. Remove heat shrink and electrical braid from
thermal switch (23). Unscrew thermal switch
from winch housing (M).
2. Installation.
a.
b.
c.
d.
Screw thermal switch (23) into winch housing
(24). Install electric braid and heat shrink
tubing on leads of switch.
Using a suitable pin installation tool, install
pins into connector (21). Twist ends of electric
braid to secure and shrink heat shrink tubing
in place.
Install clamp (20) onto connector (21) using
screws (22).
Install actuator leaves (18) and position with
microswitch assemblies (19) into boom hous-
ing. Secure using screws (15), washers (16)
and nutplates (17).
GO TO NEXT PAGE
2-143