CLEANING
WARNING
Cleaning Solvent, MIL-PRF-680, is combustible and toxic to eyes, skin and respiratory tract.
Wear protective gloves and goggles/face shield. Avoid repeated or prolonged contact. Use
only in well ventilated areas or use approved respirator as determined by local safety/industrial
hygiene personnel. Keep away from open flames or other sources of ignition.
Clean disassembled parts with Cleaning Compound, Solvent and dry with clean, lint-free cloth.
INSTALLATION
1.
Position cylinder assembly lower mounting (Figure 1, Item 4) and attach to outside scissors with bolt. Do not
tighten bolt at this time.
2.
Swing cylinder assembly into position and attach cylinder ram (upper end) (Figure 1, Item 3) to inside
scissors.
3.
Connect hydraulic hose (Figure 1, Item 1) to fitting on bottom end of cylinder assembly (Figure 1, Item 2).
END OF WORK PACKAGE