4-35. LEFT AND RIGHT HANDGRIP (LONGBOW) ASSEMBLIES 2A4 AND 2A5 REPAIR (cont)
INSTALLATION
CAUTION
Components inside the RHG contain
electrostatic discharge sensitive (ESDS)
devices. Refer to paragraph 2-8 for handling
requirements before starting this task to
prevent damage.
f. Remove old black RTV from mounting hole
(para 2-6).
g. Solder wires (7) to switch and remove tags.
h. Have solder joints inspected.
i. Apply black RTV around inside surface of
mounting hole (para 2-6).
j. Position switch with keyway alined in
mounting hole and press in firmly.
k. Apply sealing compound to the threads of
setscrew (6) (para 2-6).
l. Install setscrew and secure switch.
m. Install knob (4) and tighten setscrew (5).
END OF TASK
7
4
1
6
5
243-021