TB 1-1520-210-20-38
e. The Following Forms are Applicable and are to be Completed IAW DA Pam 738-751, 15 Jun
92.
NOTE
Unit Level Logistics System-Aviation (ULLS-A) users will use applicable
electronic (-E) forms.
(1) DA Form 2408-5-1, Equipment Modification Record (Tail Rotor Slider).
(2) DA Form 2408-13, Aircraft Status Information Record.
(3) DA Form 2408-13-1) Aircraft Inspection and Maintenance Record.
(4) DA Form 2408-15, Historical Record for Aircraft.
(5) DA Form 2408-16, Aircraft Component Historical Record.
NOTE
For ULLS-A users: Since all Collins parts have the same time between
overhaul (TBO), although that TBO differs with other manufacturers, the
masterfile needs to contain a record for the Collins CAGE code. The
serial number block is only being used as a means to identify the Collins
parts due to a marking problem. Ordinarily, no further change to the
component parts masterfile would be necessary. However, in this case,
there is no existing entry for the Collins CAGE code in the ULLS-A
masterfile. Each affected site should create an entry for the Collins Tail
Rotor Slider by following these steps:
(a) Pull up an existing data line for the Tail Rotor Slider in the component parts masterfile
area of masterfile maintenance under production processes.
(b) Change the configuration to 91, change the federal manufacturer's code to 0H0W5 (zero-
hotel-zero-whiskey-five), change the TBO to 250 hours, and enter an A in the command block to add the
new record.
(c) After making the change to the component parts masterfile, if you have one of the Collins
serial number numbers installed with an old CAGE code, uninstall the component and then reinstall it
using the new CAGE code for Collins.
(6) DA Form 2410, Component Removal and Repair/Overhaul Record (Only if Tail Rotor Slider is
replaced).
15. Weight and Balance. N/A.
16. Points of Contact.
a. For technical information, contact Mr. Steve Monaco, AMSAM-DSA-UH-U, DSN 645-0078 or
commercial (205) 955-0078. Datafax is DSN 645-6590. E-mail is <monaco-sd@redstone.army.mil>.
b. For Logistical information, contact Mr. Charles Elkins, AMSAM-DSA-UH-U, DSN 645-0073 or
commercial (205) 955-0073. Datafax is DSN 955-6590. E-mail is <elkins-ce@redstone.army.mil>.
5