n. Position shield crimp sleeve over shield.
Trim excess shield.
o. Select crimping tool with positioner as
specified in table. Insert outer contact into
crimping tool until contact is fully seated in
positioner.
p. Crimp once, rotate contact 45 degrees and
crimp a second time. After crimping second
time, diameter of shield crimp sleeve must
not be greater than 0.108 inch.
q. Lightly tug on outer contact to check that
contact holds.
r. Install contact into connector, using
installation tool specified in table.
s. Lightly tug on wire to check that contact
holds in connector.
t. Place wire in wire bundle. Secure harness
assembly with spot ties and clamps.
u. Perform electrical tests (1g above).
v. Have installation inspected.
END OF TASK